{"id":1304,"date":"2026-01-14T15:03:34","date_gmt":"2026-01-14T06:03:34","guid":{"rendered":"https:\/\/www.metran.co.jp\/?post_type=product&#038;p=1304"},"modified":"2026-10-02T14:17:03","modified_gmt":"2026-10-02T05:17:03","slug":"r100","status":"publish","type":"product","link":"https:\/\/www.metran.co.jp\/en\/product\/r100\/","title":{"rendered":"R100"},"content":{"rendered":"\n<div class=\"swell-block-fullWide pc-py-20 sp-py-20 alignfull\"><div class=\"swell-block-fullWide__inner l-article\">\n<div class=\"wp-block-columns\">\n<div class=\"wp-block-column\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"203\" height=\"466\" src=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/r100-664.jpg\" alt=\"R100\" class=\"wp-image-1099\" srcset=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/r100-664.jpg 203w, https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/r100-664-131x300.jpg 131w\" sizes=\"(max-width: 203px) 100vw, 203px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column\" style=\"flex-basis:66.66%\">\n<h1 class=\"wp-block-heading has-text-align-left is-style-default u-mb-ctrl u-mb-5 has-swl-main-background-color has-background\">R100<\/h1>\n\n\n<p><span class=\"product-tax product-tax--cat\"><a class=\"product-tax__item\" href=\"https:\/\/www.metran.co.jp\/en\/product_category\/ventilator\/\">Ventilator<\/a><\/span> <span class=\"product-tax product-tax--status\"><a class=\"product-tax__item\" href=\"https:\/\/www.metran.co.jp\/en\/product_status\/current\/\">Current Product Line<\/a><\/span><\/p>\n\n\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer u-mb-ctrl u-mb-10\"><\/div>\n\n\n\n<p class=\"has-text-align-left u-mb-ctrl u-mb-10 is-style-section_ttl wp-block-paragraph\"><span class=\"sme-text-color has-swl-main-color\"><strong><span class=\"sme-font-size has-large-font-size\"><strong>Ventilator<\/strong><br><strong>Rotary HFO\/IMV<\/strong><br><strong>Pediatric &amp; Adult Ventilator<\/strong><\/span><\/strong><\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Expanding the horizon into adult clinical care.<br>The High-Frequency Oscillatory Ventilation (HFOV) technology perfected in neonatal care now enters a broader medical field.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"swell-block-fullWide pc-py-20 sp-py-20 alignfull\" style=\"background-color:#f7f7f7\"><div class=\"swell-block-fullWide__inner l-article\">\n<h2 class=\"wp-block-heading has-text-align-left is-style-default u-mb-ctrl u-mb-10\"><strong>The Science of HFOV<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">High-Frequency Oscillatory Ventilation (HFOV) is an advanced respiratory management strategy that delivers ultra-low tidal volumes\u2014often smaller than anatomical dead space\u2014at extremely high frequencies. Long established in neonatal intensive care, this ventilation modality offers crucial clinical advantages:<br>Minimizes Lung Injury: Delivers minimal airway pressure fluctuations to significantly mitigate ventilator-induced lung injury (VILI).<br>Hemodynamic Stability: Suppresses respiratory-induced variations in blood pressure and intracranial pressure (ICP).<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"swell-block-fullWide pc-py-20 sp-py-20 alignfull\"><div class=\"swell-block-fullWide__inner l-article\">\n<p class=\"u-mb-ctrl u-mb-20 wp-block-paragraph\"><strong><span class=\"sme-font-size has-huge-font-size\">Key Features &amp; Innovation<\/span><\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left is-style-default u-mb-ctrl u-mb-10\"><strong><strong>Rotary-Driven HFOV<\/strong><\/strong><\/h2>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 20%\"><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">The heart of the R100&#8217;s capacity for high-volume, high-capacity HFOV lies in its proprietary rotary valve technology. This specialized valve enables ultra-high-speed switching of the flow and pressure generated by the internal blower. The valve surface is coated with a premium Teflon sheet, ensuring exceptional durability and superior resistance to foreign particulate matter.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"112\" height=\"84\" src=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/r100-668.jpg\" alt=\"R100\" class=\"wp-image-1100 size-full\"\/><\/figure><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"swell-block-fullWide pc-py-20 sp-py-20 alignfull\" style=\"background-color:#f7f7f7\"><div class=\"swell-block-fullWide__inner l-article\">\n<h2 class=\"wp-block-heading has-text-align-left is-style-default u-mb-ctrl u-mb-10\"><strong><strong><strong>Intuitive and easy-to-understand HFOV settingIntuitive, Visual HFOV Titration<\/strong><\/strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">When operating in HFOV mode, the integrated graphic monitor displays real-time Amplitude values and pressure fluctuations at a glance, ensuring safe and precise respiratory management. HFOV settings are finely adjusted using a straightforward combination of four core parameters:<br>HFOV settings can be adjusted by combining the settings for &#8220;mean airway pressure,&#8221; &#8220;stroke volume,&#8221; &#8220;frequency,&#8221; and &#8220;inspired oxygen concentration.&#8221;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mean Airway Pressure (MAP)<br>Stroke Volume (SV)<br>Frequency (Hz)<br>Fraction of Inspired Oxygen (FiO2)<\/p>\n\n\n\n<div class=\"wp-block-group is-row is-content-justification-center is-layout-flex wp-container-core-group-is-layout-de391324 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"224\" height=\"123\" src=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/R100-2.png\" alt=\"R100\" class=\"wp-image-1040\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"225\" height=\"68\" src=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/R100-3.png\" alt=\"R100\" class=\"wp-image-1041\"\/><\/figure>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"swell-block-fullWide pc-py-20 sp-py-20 alignfull\"><div class=\"swell-block-fullWide__inner l-article\">\n<h2 class=\"wp-block-heading has-text-align-left is-style-default u-mb-ctrl u-mb-10\"><strong><strong><strong><strong>Comprehensive Support: From HFOV to Weaning<\/strong><\/strong><\/strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The R100 is far more than a standalone oscillator; it comes equipped with a full suite of essential conventional ventilation modes. By pairing baseline modes with ventilation styles like VCV, PCV, and PSV, the system provides seamless clinical continuity from acute HFOV therapy all the way to successful weaning. Flexible Triggering Options: Clinicians can select between Pressure or Flow triggering. Highly Responsive: Combined with an automated base flow, the system delivers a lightning-fast response to even the weakest spontaneous respiratory efforts.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"swell-block-fullWide pc-py-20 sp-py-20 alignfull\" style=\"background-color:#f7f7f7\"><div class=\"swell-block-fullWide__inner l-article\">\n<h2 class=\"wp-block-heading has-text-align-left is-style-default u-mb-ctrl u-mb-10\"><strong><strong><strong><strong><strong>One-Touch Mode Selection<\/strong><\/strong><\/strong><\/strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Switching between primary ventilation modes is achieved instantaneously via a centralized selector switch.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"253\" height=\"74\" src=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/R100-1.png\" alt=\"R100\" class=\"wp-image-1039\" style=\"object-fit:cover\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"swell-block-fullWide pc-py-20 sp-py-20 alignfull\"><div class=\"swell-block-fullWide__inner l-article\">\n<p class=\"u-mb-ctrl u-mb-20 wp-block-paragraph\"><strong><span class=\"sme-font-size has-huge-font-size\">Advanced Clinical Support &amp; Design<\/span><\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left is-style-default u-mb-ctrl u-mb-10\"><strong><strong><strong><strong><strong><strong>Manual Sigh Function<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/h2>\n\n\n\n<p class=\"u-mb-ctrl u-mb-10 wp-block-paragraph\">Features a dedicated manual sigh mechanism available during HFOV mode. By holding down the &#8220;Manual Breath&#8221; button, clinicians can apply a sustained recruitment maneuver tailored to the patient, up to a maximum duration of 10 seconds.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"swell-block-fullWide pc-py-20 sp-py-20 alignfull\" style=\"background-color:#f7f7f7\"><div class=\"swell-block-fullWide__inner l-article\">\n<h2 class=\"wp-block-heading has-text-align-left is-style-default u-mb-ctrl u-mb-10\"><strong><strong><strong><strong><strong><strong>High-Performance Inspiratory &amp; Expiratory Valves<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Engineered with premium, ultra-responsive valves, the R100 ensures high-speed, exceptionally precise flow control across all ventilation modalities.<br>The system instantaneously interprets and adapts to the patient\u2019s expiratory demand, dramatically optimizing synchrony.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"swell-block-fullWide pc-py-20 sp-py-20 alignfull\"><div class=\"swell-block-fullWide__inner l-article\">\n<h2 class=\"wp-block-heading has-text-align-left is-style-default u-mb-ctrl u-mb-10\"><strong><strong><strong><strong><strong><strong>Safety-First Engineering<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/h2>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 20%\"><div class=\"wp-block-media-text__content\">\n<h3 class=\"wp-block-heading u-mb-ctrl u-mb-10 is-style-default\">Cartridge-Style Diaphragm:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The diaphragm that converts rotary valve pressure into physical oscillations features a detachable cartridge system. Housed under a clear dome, it offers excellent visibility for effortless maintenance.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"101\" height=\"94\" src=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/r100-672.jpg\" alt=\"R100\" class=\"wp-image-1101 size-full\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group u-mb-ctrl u-mb-20\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-media-text is-stacked-on-mobile u-mb-ctrl u-mb-0\" style=\"grid-template-columns:20% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"101\" height=\"94\" src=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/r100-673.jpg\" alt=\"R100\" class=\"wp-image-1102 size-full\"\/><\/figure><div class=\"wp-block-media-text__content\">\n<h3 class=\"wp-block-heading u-mb-ctrl u-mb-10 is-style-default\">Blower Intake Filter:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">During HFOV, the internal blower continuously generates massive flow volumes at high speeds. A heavy-duty intake filter prevents ambient dust and airborne contaminants from entering the system. The filter is easily replaceable.<\/p>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group u-mb-ctrl u-mb-20\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading u-mb-ctrl u-mb-10\">Expiratory Filter System:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Integrated directly into the expiratory circuit, this system dries exhaled gases and filters out microbial contaminants prior to exhaust, actively contributing to hospital infection control protocols.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group u-mb-ctrl u-mb-20\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading u-mb-ctrl u-mb-10\">Automated Smart Alarms:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To prevent human error and misconfiguration, airway pressure alarms automatically calculate and set boundaries based on real-time measured values whenever ventilation parameters are modified. Alarm limits can still be manually adjusted at any time.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading u-mb-ctrl u-mb-10\">Advanced Graphic Monitoring:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Equipped with a dedicated graphical display, the R100 allows for real-time tracking and evaluation\u2014ranging from deep pressure analysis during HFOV to full waveform analysis during conventional ventilation.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" width=\"372\" height=\"70\" src=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/r100-674.jpg\" alt=\"R100\" class=\"wp-image-1103\" style=\"width:600px\" srcset=\"https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/r100-674.jpg 372w, https:\/\/www.metran.co.jp\/cms\/wp-content\/uploads\/2026\/10\/r100-674-300x56.jpg 300w\" sizes=\"(max-width: 372px) 100vw, 372px\" \/><\/figure>\n<\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Expanding the horizon into adult clinical care. The High-Frequency Oscillatory Ventilation (HFOV) technology perfected in neonatal care now enters a broader medical field.<\/p>\n","protected":false},"author":3,"featured_media":244,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"swell_btn_cv_data":"","_locale":"en_US","_original_post":"https:\/\/metran.zenith-web-creations.com\/?post_type=product&#038;p=165","footnotes":""},"product_category":[16],"product_status":[19],"class_list":["post-1304","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-ventilator","product_status-current","en-US"],"_links":{"self":[{"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/product\/1304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/comments?post=1304"}],"version-history":[{"count":1,"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/product\/1304\/revisions"}],"predecessor-version":[{"id":1305,"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/product\/1304\/revisions\/1305"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/media\/244"}],"wp:attachment":[{"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/media?parent=1304"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/product_category?post=1304"},{"taxonomy":"product_status","embeddable":true,"href":"https:\/\/www.metran.co.jp\/wp-json\/wp\/v2\/product_status?post=1304"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}